Copyright 2022 Dial Instruments Pte Ltd
Magneto strictive level measurement MS350
MSLMMS350

Magneto strictive level measurement MS350

chatAsk
Share

Product Description

Applications

Chemical measurement and high precision measurement of blending tanks
 

Features

  • Based on the Wiedemann effect
  • High accuracy (±1mm/±0.1%F.S.) and high resolution
  • Low cost

Principle of Operation

Principle of Operation  
Current pulse is applied to one end of magnetostrictive wire.
Circular magnetic is generated, encompassing the entire wire.
Magnetic field from the position magnet and the circular magnetic field interact.
The interaction produces a strain pulse.
Travel time of the strain pulse to the pick-up is proportional to the distance the pulse travels.
The time elapsed is measured multiple times. Remarkably accurate measurement is ensured.
 
Copyright 2022 Dial Instruments Pte Ltd